All our calibration standards are traceable to the National Institute of Standards and Technology (NIST), ensuring the highest level of accuracy. Our wind/airflow standard is calibrated in the NIST laser doppler wind tunnel, as this is the only lab in the country that can provide the calibration accuracy we require.

NIST-traceable calibration ensures your Kestrel meets the highest accuracy standards required in regulated fields like research, safety, and environmental monitoring. Each service includes a NIST Calibration Report and Certificate with "as found" and "as left" values, and sensors are adjusted when possible to restore accuracy.

When can you purchase NIST-Traceable Calibration?

  • At Time of Purchase: Add NIST calibration for each required sensor before checkout. No serial number is needed. Please type the word "NEW" in the Serial Number field above. Your calibration report and certificate will be included with your order. Please allow an additional 3–5 days for processing.
  • After Purchase (Recalibration): Ideal for annual maintenance or industry compliance. Select the calibration you need, provide your device's serial number, and return the unit to the address below. Your completed NIST Calibration Report and Certificate will be returned with your Kestrel.

Shipping Your Kestrel for NIST Calibration

After placing your order, note your order number and clearly write it on the outside of your shipping box.

Then securely pack your Kestrel and send it to:

Nielsen-Kellerman
21 Creek Circle
Boothwyn, PA 19061
Attn: ORDER#####

Shipping Notes

  • Customers are responsible for the cost of shipping their unit to NK.
  • Return ground shipping is free within the U.S. and Canada for both warranty and non-warranty services.
  • Expedited and international return shipping is available at an additional charge.

International Returns

If you're shipping your unit from outside the U.S., please include the following on each line item of the customs invoice to avoid unnecessary duties or taxes:

  • Harmonized Code: 9015.80.8080
  • Description: Return for Warranty Repair of U.S. Manufactured Goods

You'll also receive these shipping instructions via email. To help us process your calibration quickly, please be sure to:

  • Include your Order Number on the outside of the box
  • Optionally, print and include your order confirmation inside the package

90-Day Limited Warranty on Calibration Services

All repairs and tune-ups are warrantied for a period of ninety (90) days from the date of service (1) that service was performed in a competent and workmanlike manner and (2) that all parts used to service your product were free from defects in materials and workmanship. The foregoing warranty is an express limited warranty and in the event of breach, NK will either (i) re-perform the service, (ii) repair or replace the part, or (iii) refund the cost of the service provided. Products will continue to be covered by their original limited warranty after repair or tune-up, or by this limited repair warranty, whichever is longer.

Questions about NIST calibration or shipping your Kestrel?

Send us a message or call us at (610) 447-1555.

Measurement NIST Calibration Points Factory Calibration Points Models Correction Included?
Wind Speed / Air Flow ~600 fpm
~1200 fpm
~300 fpm
~1200 fpm
All Kestrel Meters Yes — Impeller will be replaced with a new calibrated impeller if required.
Temperature -10°
50°C
1 hour
equilibration
50°C
1 hour
equilibration
2000 and above DROP No — Temperature sensor reading is not correctable. However, it is rare for this sensor to drift out of specification.
Black Globe Temperature -10°
50°C
1 hour
equilibration
50°C
1 hour
equilibration
4400
5400
No — Temperature sensor reading is not correctable. However, it is extremely rare for this sensor to drift out of specification.
Humidity ~33% RH
~75% RH
~33% RH
~75% RH
3000 & 3500
4000 Series
Yes — Sensor will be corrected to perform within specification.
5 Series
DROP D2, D3
For the DROPs, the humidity sensor is not adjustable. However, it is rare for this sensor to drift out of specification. (Firmware revision may make sensor correction available in the future.)
Pressure Ambient Pressure
Lower Limit Pressure
  2500 & 3500
4000 Series
5 Series
Yes — sensor will be corrected
NIST Calibration will include a detailed, dated, unit-serialized, NIST Calibration Report and Certificate showing as found and as left values, standard values, acceptable range, and deviation. Factory Calibration will include a dated, signed Certificate of Conformity for the measurements tested.
Turnaround for both NIST and Factory Calibration services is typically 7–10 days after receipt.

View a sample of the test report for NIST Calibrated units.

View a sample of a Cerificate of Conformity.

View our Tune-up product.

Overview of Tune-up & Calibration Services


Downloads

Kestrel 5 Series Instruction Manuals

User Guide Relative Humidity Calibration Kit For Kestrel 5 Series, 4 Series and Kestrel 3000-3500 Series (DROPs currently cannot be recalibrated)

Kestrel 5 Series Instruction Manuals

User Guide Relative Humidity Calibration Kit For Kestrel 5 Series, 4 Series and Kestrel 3000-3500 Series (DROPs currently cannot be recalibrated)


Downloads

Kestrel 5 Series Instruction Manuals

User Guide Relative Humidity Calibration Kit For Kestrel 5 Series, 4 Series and Kestrel 3000-3500 Series (DROPs currently cannot be recalibrated)

Product Questions


Downloads

Kestrel 5 Series Instruction Manuals

User Guide Relative Humidity Calibration Kit For Kestrel 5 Series, 4 Series and Kestrel 3000-3500 Series (DROPs currently cannot be recalibrated)


Downloads

Kestrel 5 Series Instruction Manuals

User Guide Relative Humidity Calibration Kit For Kestrel 5 Series, 4 Series and Kestrel 3000-3500 Series (DROPs currently cannot be recalibrated)

Other Items you Might Consider
Accessories